Overview
Engineering reference data for HVAC Terms in HVAC systems.
Key Formulas
Sensible Heat
Heat causing temperature change.
Latent Heat
Heat causing moisture change.
COP (Cooling)
Coefficient of performance.
Variables
| Symbol | Description | Unit |
|---|---|---|
| Heat transfer | W | |
| Mass flow rate | kg/s | |
| Specific heat of air | J/(kg·K) | |
| Temperature difference | K |
HVAC Term Definitions
| Term | Definition |
|---|---|
| ABSOLUTE HUMIDITY | The weight of water vapor in a given amount of air. |
| ABSOLUTE PRESSURE | Pressure measured with the base of zero. |
| ABSOLUTE TEMPERATURE | A temperature scale expressed in degrees °F or °C using absolute zero as a base (Rankine or Kelvin scale). |
| ABSOLUTE ZERO | The temperature at which molecular activity theoretically ceases: -459.67°F or -273.15°C. |
| AIR CONDITIONING | The process of controlling the temperature, humidity, cleanliness, and distribution of the air. |
| AMBIENT | Refers to the temperature surrounding a body or unit under test. |
| ATMOSPHERIC PRESSURE | The weight of a 1 unit column of the earth's atmosphere. |
| BI-METAL | Two metals with different rates of expansion fastened together; warps when heated/cooled to open/close a switch or valve. |
| BOILING POINT | The temperature at which the addition of any heat will begin a change of state from a liquid to a vapor. |
| BRITISH THERMAL UNIT (BTU) | The amount of heat necessary to change the temperature of 1 pound of pure water 1 degree Fahrenheit (°F). |
| CAPILLARY TUBE | A refrigerant control consisting of a small diameter tube which controls flow by restriction, sized by inside diameter and length for each application. |
| CENTIGRADE | A temperature scale with the freezing point of water 0°C and the boiling point 100°C at sea level. |
| CHECK VALVE | A valve designed to permit flow in one direction only. |
| COMPRESSION | The reduction of volume of a vapor or gas by mechanical means. |
| COMPRESSION RATIO | The ratio determined by dividing the discharge pressure by the suction pressure. |
| COMPRESSOR | A mechanical device used to compress gases; main types: screw, scroll, reciprocating, centrifugal, and rotary. |
| CONDENSATION POINT | The temperature at which the removal of any heat will begin a change of state from a vapor to a liquid. |
| CONDENSING MEDIUM | The substance, usually air or water, to which the heat in a condenser is transferred. |
| CONDENSING UNIT | The portion of a refrigeration system where the compression and condensation of refrigerant is accomplished (the 'high side'). |
| CONDUCTION | The transfer of heat from molecule to molecule within a substance. |
| CONTACTOR | An electromagnetic actuated relay, usually used to close the circuit to a compressor. |
| CONVECTION | The transfer of heat by a moving fluid. |
| COOLING ANTICIPATOR | A resistance heater in parallel with the cooling circuit that adds heat during the off cycle to shorten it. |
| COP | Ratio of work performed or accomplished as compared to the energy used. |
| CUBIC FEET PER MINUTE (CFM) | A common means of assigning quantitative values to volumes of air in transit. |
| CYCLE | The complete course of operation of a refrigerant back to a selected starting point in a system. |
| DENSITY | Mass or weight per unit of volume. |
| DISCHARGE LINE | A tube used to convey the compressed refrigerant vapor from the compressor to the condenser inlet. |
| DISCHARGE PRESSURE | The pressure read at the compressor outlet; also called head pressure or high side pressure. |
| DRY AIR | Air which contains no moisture vapor. |
| DRY BULB TEMPERATURE | Temperature read with an ordinary thermometer. |
| EFFECTIVE TEMPERATURE | An arbitrary concept combining temperature, humidity, and air movement into a single value as sensed by the human body. |
| ENTHALPY | Total amount of heat in one pound (kg) of a substance calculated from an accepted temperature base, expressed in BTU's per pound mass (J/kg). |
| EQUIVALENT LENGTH | That length of straight tubing with the same pressure drop as a fitting, valve, or accessory of the same nominal size. |
| EVAPORATIVE COOLING | The cooling effect of vaporization of a liquid in a moving air stream. |
| EVAPORATOR | A device in which a liquid refrigerant is vaporized, often with some super-heating. |
| EVAPORATOR SUPERHEAT | The actual temperature of the refrigerant vapor at the evaporator exit compared to the saturated vapor temperature indicated by the suction pressure. |
| EXTERNAL STATIC PRESSURE | The sum of the static and velocity pressures of a moving air system at the point of measurement. |
| FAHRENHEIT | A temperature scale with the freezing point of water 32°F and the boiling point 212°F at sea level. |
| FEET PER MINUTE (FPM) | A term assigned to the velocity of a moving air stream. |
| FILTER-DRIER | A device that removes moisture, acid, and foreign matter from the refrigerant. |
| FLASH GAS | Instantaneous evaporation of some liquid refrigerant at the metering device due to pressure drop, cooling the remaining liquid to the desired evaporation temperature. |
| FREEZING POINT | The temperature at which the removal of any heat will begin a change of state from a liquid to a solid. |
| SATURATED VAPOR | Vapor in contact with a liquid. |
| SATURATION | A condition of stable equilibrium of a vapor and a liquid. |
| SENSIBLE HEAT | Heat that can be measured or felt; always causes a temperature rise. |
| SIGHT GLASS | A glass installed in the liquid line for visual inspection of liquid refrigerant to detect vapor and monitor moisture content. |
| SLUGGING | A condition where liquid enters the compressor, causing hammering and possible damage. |
Additional HVAC Formulas
-
Compression Ratio: where is discharge pressure and is suction pressure.
-
Coefficient of Performance (COP): For refrigeration systems, this is often expressed as: where is the cooling effect and is the work input.