12 V 线规与电流、回路长度
按电流和回路总长度选择 12 V 铜导线的 AWG 规格,设计压降限值为 3%。
概述
使用此参考为 12 V 直流电路选择铜 AWG 线规,当design voltage drop is limited to 3% (0.36 V). The length in the table is the total circuit length: from the source to the load and back to the source. It is not the one-way distance.
这是一个电压降选择指南,不是规范载流量表。导体绝缘、安装lation method, ambient temperature, terminations, and local electrical rules can require a different conductor or overcurrent-protection rating.
How to Use the Table
- 测量从电源到负载再返回的完整电流路径。
- 选择该总长度的行和电路电流的列。
- The intersecting value is the AWG size used by the source reference.
For example, a 15 ft total circuit carrying 15 A corresponds to 12 AWG. A 15 ft one-way run has a 30 ft total circuit length, so use the 30 ft row instead.
12 V Copper Wire Gauge Selection (3% Voltage Drop)
| 15 | 16 | 12 | 10 | 10 | 8 | 8 | 6 | 6 | 4 | 4 |
| 20 | 14 | 12 | 10 | 8 | 8 | 6 | 6 | 4 | 4 | 4 |
| 25 | 14 | 10 | 8 | 8 | 6 | 6 | 4 | 4 | 2 | 2 |
| 30 | 12 | 10 | 8 | 6 | 6 | 4 | 4 | 2 | 2 | 2 |
| 40 | 12 | 8 | 6 | 6 | 4 | 4 | 2 | 2 | 1 | 1/0 |
| 50 | 10 | 8 | 6 | 4 | 4 | 2 | 2 | 1 | 1/0 | 1/0 |
| 60 | 10 | 6 | 6 | 4 | 2 | 2 | 1 | 1/0 | 2/0 | 2/0 |
| 70 | 10 | 6 | 4 | 2 | 2 | 2 | 1/0 | 2/0 | 2/0 | 3/0 |
| 80 | 8 | 6 | 4 | 2 | 2 | 1 | 1/0 | 2/0 | 3/0 | 3/0 |
| 90 | 8 | 4 | 4 | 2 | 1 | 1/0 | 2/0 | 3/0 | 3/0 | 4/0 |
来源: Engineering ToolBox
1 ft = 0.3048 m.
12 V Cable Table-Derived Maximum-Current Charts
These charts are calculated from the selection table above; they are not digitized copies of the original graphic. For each total circuit length and AWG, a plotted value is the highest current column in that row that specifies that AWG. If an AWG does not occur in a row, its point is blank rather than zero. The feet and metres charts show the same derived values.
Table-derived AWG series
- 4/0 AWG
- 3/0 AWG
- 2/0 AWG
- 1/0 AWG
- 1 AWG
- 2 AWG
- 4 AWG
- 6 AWG
- 8 AWG
- 10 AWG
- 12 AWG
- 14 AWG
- 16 AWG
12 V Cables — Table-Derived Maximum Current (feet)
12 V Cables — Table-Derived Maximum Current (metres)
Voltage-Drop Formula
For a two-conductor circuit, use the total circuit length directly:
Where is current in A, is the conductor DC resistance in , and is the complete circuit length in ft. The resistance value must be in ohms, not milliohms.
Voltage Drop Calculator
The default resistance is 1.588 for 12 AWG solid copper at 20 °C. With the default 15 ft total circuit and 15 A load, the calculated drop is about 0.357 V (about 3.0%). Use manufacturer data for the actual conductor, temperature, and construction.
12 V 电缆 电压 Drop
Important Limits
- Protect the conductor with correctly selected overcurrent protection. A fuse or circuit breaker cannot be chosen from AWG alone; use the applicable electrical code and the conductor manufacturer’s installation data.
- Resistance changes with conductor temperature and construction. Use the actual conductor’s published DC resistance when voltage drop is critical.
- If the chassis is used as a return path, include the resistance of the complete return path rather than assuming that only the supply conductor matters.
- This reference is for copper conductors in a 12 V system with a 3% voltage-drop design target. It does not replace code-required ampacity, derating, or termination checks.