The Moody diagram is a dimensionless chart relating the Darcy friction factor (λ or f) to Reynolds number (Re) and relative roughness (k/d) for fully developed flow in circular pipes. It is the standard tool for estimating pipe friction losses in the Darcy-Weisbach equation and covers laminar, transitional, and turbulent flow regimes.

Two conventions exist for the friction factor. The SI (Darcy) friction factor λ is four times the Imperial (Fanning) friction factor f. Always confirm which convention applies before using a value.

關键公式

Reynolds Number

Re=ρvdμ=vdν\text{Re} = \frac{\rho \, v \, d}{\mu} = \frac{v \, d}{\nu}

Determines whether flow is laminar (Re < 2300), transitional (2300 < Re < 4000), or turbulent (Re > 4000).

Darcy-Weisbach Head Loss

hf=λLdv22gh_f = \lambda \, \frac{L}{d} \, \frac{v^2}{2g}

Major (friction) head loss over pipe length L.

Relative Roughness

r=kdr = \frac{k}{d}

Ratio of pipe absolute roughness to inner diameter; this locates the correct curve on the Moody diagram.

Colebrook-White Equation (implicit, turbulent)

1λ=2.0log10 ⁣(k/d3.7+2.51Reλ)\frac{1}{\sqrt{\lambda}} = -2.0 \, \log_{10}\!\left(\frac{k/d}{3.7} + \frac{2.51}{\text{Re}\,\sqrt{\lambda}}\right)

An implicit correlation that reproduces the turbulent zone of the Moody diagram. Must be solved iteratively.

Laminar Friction Factor

λ=64Re\lambda = \frac{64}{\text{Re}}

Exact for all laminar flow (Re < 2300).

變量

符號說明單位
λDarcy (SI) friction factor
fFanning (Imperial) friction factor
ReReynolds number
kAbsolute pipe roughnessm
dPipe inner diameterm
rRelative roughness (k/d)
vMean flow velocitym/s
ρFluid densitykg/m³
μDynamic viscosityPa·s
ν運動黏度m²/s
hfFriction head lossm
LPipe lengthm
gGravitational acceleration9.81 m/s²

Convention relationship: λ = 4f

Absolute Roughness for Common Pipe Materials

8
新的清潔管道的典型絕對粗糙度值
管道 材料
(mm)
Drawn tubing (brass, lead, glass)0.0015
PVC / plastic pipe0.0015
Commercial steel / wrought iron0.045
Galvanized iron0.15
Cast iron0.26
Concrete (smooth)0.3
Riveted steel0.9
Corrugated metal45

來源: engineeringtoolbox.com

Roughness by Flow Regime

5
各流動狀態下摩擦因數的變化行為
流量 Regime
摩擦 係數 Behavior
Re < 2300λ = 64 / Re (independent of roughness)
Transitional2300 < Re < 4000Indeterminate; interpolate between laminar and turbulent values
Turbulent (smooth pipe)Re > 4000Depends on Re only; use Blasius or Colebrook-White
Turbulent (transition)Re > 4000Depends on both Re and k/d
Fully rough (turbulent)Re → ∞Depends on k/d only; friction factor becomes constant

來源: engineeringtoolbox.com

Relative Roughness Calculator

Head Loss Calculator

Darcy-Weisbach 摩擦 扬程 Loss

單位換算器

Moody 圖 單位 转換器

Interactive Moody Diagram Data

The original Moody diagram image is represented below as calculated friction-factor curves. The laminar curve uses λ = 64/Re; turbulent curves use the Swamee-Jain explicit approximation for selected relative roughness values.

Moody 圖 摩擦-係數 Curves

Example - Reading the Moody Diagram

For a PVC pipe with very small relative roughness and Reynolds number near (10^7), the Moody diagram is read on the turbulent smooth-pipe side. The Darcy friction factor is approximately ( \lambda \approx 0.008 - 0.01 ), depending on the exact roughness assumption. This value can then be used directly in the Darcy-Weisbach equation for SI calculations. If a Fanning friction factor is required instead, divide the Darcy value by four.

Laminar vs Turbulent Friction Comparison

8
層流與湍流狀態下摩擦因數值的比較(k/d = 0.001)
λ Turbulent (k/d = 0.001)
5000.128
10000.064
20000.032
40000.041
100000.032
1000000.021
10000000.02
100000000.019

來源: engineeringtoolbox.com

原始源圖

The following original source images are preserved to avoid losing visual reference material. When an image contains chart or tabular data, its extracted values are represented in the page tables, calculators, or interactive charts; remaining images are retained as visual source references.

moody diagram Moody diagram

工程要點

  • Transient zone caution (2300 < Re < 4000): The friction factor cannot be reliably determined because flow alternates between laminar and turbulent states. Conservative practice is to use the higher (turbulent) friction factor value at Re = 4000 for design.
  • Convention trap: The Darcy (λ) and Fanning (f) friction factors differ by a factor of four (λ = 4f). Head loss equations published with f require a factor of four more than those with λ. Always confirm which version is in use.
  • Roughness changes over time: New-pipe roughness values assume clean surfaces. Corrosion, scale, and biological growth can increase effective roughness by an order of magnitude in service. Apply safety factors accordingly.
  • Colebrook-White is implicit: Because λ appears on both sides of the Colebrook-White equation, it requires iteration. The Swamee-Jain approximation provides an explicit alternative accurate to about ±1% for 10⁻⁶ < k/d < 10⁻² and 5000 < Re < 10⁸.
  • Non-circular pipes: Use hydraulic diameter dₕ = 4A/P in place of d. The Moody diagram then provides an approximation, but accuracy decreases as the cross-section deviates from circular.
  • Minor vs major losses: The Moody diagram addresses only major (friction) losses. Fittings, bends, and valves are accounted for separately as minor losses using loss coefficients K or equivalent lengths.

參考资料

  • Engineering ToolBox — Moody Diagram
  • Colebrook, C. F. "Turbulent Flow in Pipes." Journal of the Institution of Civil Engineers, 1939.
  • Moody, L. F. "Friction Factors for Pipe Flow." Transactions of the ASME, 1944.