Overview

Engineering reference data for Vacuum Pumps Exhaust Piping in pumps.

Key Formulas

Pump Power

P=QHρgηP = \frac{Q \cdot H \cdot \rho \cdot g}{\eta}

Hydraulic power / efficiency.

NPSH Available

NPSHa=Psρg+vs22gPvρgNPSH_a = \frac{P_s}{\rho g} + \frac{v_s^2}{2g} - \frac{P_v}{\rho g}

Net Positive Suction Head available.

Affinity Laws

Qn,Hn2,Pn3Q \propto n, \quad H \propto n^2, \quad P \propto n^3

Flow, head, power vs speed.

Variables

Symbol Description Unit
PP Power W
QQ Flow rate m³/s
HH Head m
η\eta Efficiency
nn Rotational speed RPM