Engineering reference data for Drainage Fixture Units (DFU) and Pipe Sizing in sanitary drainage.

Key Formulas

Manning's Equation

Q=1nARh2/3S1/2Q = \frac{1}{n} A R_h^{2/3} S^{1/2}

Open channel flow.

Slope

S=ΔhLS = \frac{\Delta h}{L}

Hydraulic gradient.

Variables

Symbol Description Unit
QQ Flow rate m³/s
nn Manning roughness
AA Flow area
RhR_h Hydraulic radius m