Overview
Orifice plates, nozzles, and Venturi meters are differential pressure flow meters. They create a constriction that increases velocity and decreases pressure, allowing flow rate calculation from the pressure differential.
Key Formulas
Flow Rate
Discharge through a differential pressure meter.
Beta Ratio
Ratio of throat diameter to pipe diameter.
Variables
| Symbol | Description | Unit |
|---|---|---|
| Volume flow rate | m³/s | |
| Discharge coefficient | — | |
| Throat area | m² | |
| Pressure differential | Pa | |
| Fluid density | kg/m³ | |
| Diameter ratio | — |