Key Formulas

Unit Conversion

y=xky = x \cdot k

Multiply by conversion factor.

Linear Interpolation

y=y1+(xx1)(y2y1)x2x1y = y_1 + \frac{(x - x_1)(y_2 - y_1)}{x_2 - x_1}

Estimate between two known points.

Percentage

p=partwhole×100%p = \frac{\text{part}}{\text{whole}} \times 100\%

Part as fraction of whole.

Variables

Symbol Description Unit
xx Input value
yy Output value
kk Conversion factor

Septic Tank Capacities

Soil Absorption Capacities

Leach Field Sizing

The required leach field area is calculated by dividing the daily wastewater volume by the soil absorption capacity:

A=QCA = \frac{Q}{C}

Where:

  • AA = required leach field area (ft²)
  • QQ = total daily wastewater loading (gallons/24hr)
  • CC = soil absorption capacity (gal/ft²/24hr)

Example: For a single family dwelling with Q=1200Q = 1200 gallons in fine sand soil (C=4C = 4 gal/ft²):

A=12004=300 ft2A = \frac{1200}{4} = 300 \text{ ft}^2

Leach Line Design Guidelines

Parameter Imperial Metric
Maximum length per line 100 ft 30 m
Minimum spacing between lines 10 ft 3 m
Minimum trench depth 12 in 0.3 m
Elevation grade ~1% ~1%

Note: In freezing climates, leach lines must be installed below the frost depth.