Drainage Vents

Reference data and engineering information about drainage vents for piping systems applications.

drainagevents

Overview

Engineering reference data for Drainage Vents in piping systems.

Key Formulas

Continuity

A1v1=A2v2A_1 v_1 = A_2 v_2

Mass conservation in pipe flow.

Pressure Drop

ΔP=fLDρv22\Delta P = f \frac{L}{D} \frac{\rho v^2}{2}

Darcy-Weisbach equation.

Pipe Area

A=πD24A = \frac{\pi D^2}{4}

Cross-sectional area of a pipe.

Variables

Symbol Description Unit
DD Pipe diameter m
vv Flow velocity m/s
ΔP\Delta P Pressure drop Pa
ff Friction factor

Vent Types and Applications

Different vent configurations serve specific purposes in drainage systems:

Vent Type Description Application
Individual Vents Serve a single fixture May connect to another vent extending to open air
Relief Vents Provide additional air to the drainage system Required when primary vent is too far from fixture
Circuit Vents Serve multiple fixtures Installed before the last fixture, extends to open air or connects to another vent
Branch Vents Extend horizontally Connect multiple vents together
Stack Vents Used solely for venting purposes Extend vertically through the building

Vent Sizing Requirements

Standard vent sizing rules:

  • Individual vents: Minimum one-half the diameter of the drain served (no less than 1¼" / 32 mm)
  • Relief vents: Minimum one-half the diameter of the drain served (no less than 1¼" / 32 mm)
  • Circuit vents: Minimum one-half the diameter of the drain served (no less than 1¼" / 32 mm)

Vents are typically sized using the Developed Length method, which measures the total linear footage of pipe comprising the vent system.

Maximum Length of Vent Stacks and Relief Vents

Approved Drainage and Vent Pipe Materials

Interactive Charts

References